Zelio Control

RM22UB34

RM22UB34

Voltage control relay 80V…300Vac/dc, 2 C/O

Add to Quote
Category:

Product Description

Voltage control relay 80V…300Vac/dc, 2 C/O

Technical Specifications

Download Product Datasheet

Main
range of product
Zelio Control
product or component type
Modular measurement and control relays
relay type
Voltage control relay
network number of phases
1 phase
supply circuit type
DC
relay name
RM22UA
relay monitored parameters
Overvoltage and undervoltage detection
time delay type
Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
switching capacity in VA
2000 VA
measurement range
80...300 V voltage AC/DC 50/60 Hz
Complementary
reset time
1500 ms at maximum voltage
maximum switching voltage
250 V AC
minimum switching current
10 mA at 5 V DC
maximum switching current
8 A AC
[Us] rated supply voltage
110...240 V AC 50/60 Hz
supply voltage limits
60…280 V AC
power consumption in VA
5 VA AC
maximum power consumption in W
2 W DC
supply voltage frequency
50...60 Hz +/- 10 %
output contacts
2 C/O
nominal output current
8 A
hysteresis
5…50 % adjustable of threshold setting
run-up delay at power-up
600 ms
maximum measuring cycle
250 ms measurement cycle as true rms value
repeat accuracy
+/- 0.5 % for input and measurement circuit
+/- 2 % for time delay
measurement error
< 1 % over the whole range with voltage variation
0.2 %/°C with temperature variation
response time
<= 500 ms
overvoltage category
III conforming to IEC 60664-1
insulation resistance
> 100 MOhm at 500 V DC conforming to IEC 60255-27
mounting position
Any position
connections - terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
tightening torque
0.6…1 N.m conforming to IEC 60947-1
housing material
Self-extinguishing plastic
status LED
LED (yellow)relay ON:
LED (green)power ON:
mounting support
35 mm DIN rail conforming to EN/IEC 60715
electrical durability
100000 cycles
mechanical durability
10000000 cycles
utilisation category
AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
safety reliability data
MTTFd = 433.7 years
B10d = 400000
contacts material
Cadmium free
width
22.5 mm
product weight
0.09 kg
Environment
immunity to microbreaks
20 ms
electromagnetic compatibility
Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
standards
EN/IEC 60255-1
product certifications
CCC
China RoHS
CE
CSA
EAC
UL
GL
RCM
ambient air temperature for storage
-40…70 °C
ambient air temperature for operation
-20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DC
relative humidity
93…97 % at 25…55 °C conforming to IEC 60068-2-30
vibration resistance
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
shock resistance
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
IP degree of protection
IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
pollution degree
3 conforming to IEC 60664-1
dielectric test voltage
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Offer Sustainability
Sustainable offer status
Green Premium product
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Documents

More Information

Please visit the product page on our main site for more information.


Learn more