産品概述
Electronic pressure sensors, Pressure sensors XM, Display & switch ZMLP, 24 VDC, 4…20 mA, PNP, hysteresis, M12
Electronic pressure sensors, Pressure sensors XM, Display & switch ZMLP, 24 VDC, 4…20 mA, PNP, hysteresis, M12
Main | |
---|---|
Range of product | OsiSense XM |
Product or component type | Electronic pressure sensors |
Device short name | ZMLP |
Complementary | |
Display range | -14.5...6000 |
[Us] rated supply voltage | 24 V DC SELV (voltage limits: 17…33 V) |
Current consumption | <= 50 mA |
Electrical connection |
Female connector M12, 2 pins
Male connector M12, 4 pins |
Type of output signal | Analogue + discrete |
Analogue output function | 4...20 mA |
Discrete output type | Solid state PNP, NO/NC programmable |
Switching function | Hysteresis |
Maximum switching current | 200 mA |
Maximum voltage drop | 2 V |
Adjustable range of switching point on rising pressure | 5…98 % of selected display range |
Adjustable range of switching point on falling pressure | 2…95 % of selected display range |
Minimum differential travel | 3 % of selected display range |
Marking | CE |
Front material | Polyester |
Housing material | PBT Valox |
Operating position | Any position |
Protection type |
Reverse polarity
Overload protection Short-circuit protection Overvoltage protection |
Response time on output |
<= 3 ms for analog output
<= 3 ms for discrete output |
Display type | 4 digits 7 segments |
Local signalling | 1 LED (yellow) for light ON when switch is actuated |
Response time | 300 ms |
Maximum delay first up | 100 ms |
Accuracy | <= - 0.1 % of the measuring range |
Measurement accuracy | <= 1 % of the measuring range |
Display accuracy | <= 1 % of the measuring range |
Mechanical durability | 10000000 cycles |
Depth | 42 mm |
Height | 77 mm |
Width | 41 mm |
Net weight | 0.103 kg |
[Uimp] rated impulse withstand voltage | 0.5 kV DC |
Environment | |
Product certifications |
EAC
cULus |
Standards |
EN/IEC 61000-6-4
UL 508 EN/IEC 61000-6-2 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -30…80 °C |
IP degree of protection |
IP67 conforming to EN/IEC 60529
IP65 conforming to EN/IEC 60529 IP69K conforming to DIN 40050 |
Vibration resistance | 5 gn (f= 10…2000 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 25 gn conforming to EN/IEC 60068-2-27 |
Electromagnetic compatibility |
Immunity to conducted RF disturbances: 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
Surge immunity test: 1 kV conforming to EN/IEC 61000-4-5 Electrical fast transient/burst immunity test: 2 kV conforming to EN/IEC 61000-4-4 Susceptibility to electromagnetic fields: 10 V/m 80...2000 MHz conforming to EN/IEC 61000-4-3 Electrostatic discharge immunity test: 8 kV air, 4 kV contact conforming to EN/IEC 61000-4-2 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 4.2 cm |
Package 1 Width | 4.6 cm |
Package 1 Length | 8.4 cm |
Package 1 Weight | 106 g |
Unit Type of Package 2 | S01 |
Number of Units in Package 2 | 24 |
Package 2 Height | 15 cm |
Package 2 Width | 15 cm |
Package 2 Length | 40 cm |
Package 2 Weight | 2.705 kg |
Offer Sustainability | |
Sustainable offer status | Green Premium product |
REACh Regulation | REACh Declaration |
EU RoHS Directive | EU RoHS Declaration |
Mercury free | Yes |
RoHS exemption information | Yes |
Environmental Disclosure | Product Environmental Profile |
Circularity Profile | End of Life Information |
California proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |