Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, straight, 2NC+1 NO, ISO M20
Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, straight, 2NC+1 NO, ISO M20
Main | |
---|---|
Range of product | Telemecanique Emergency stop rope pull switches XY2C |
Product or component type | Latching emergency stop rope pull switch |
Device short name | XY2C |
Housing colour | Red RAL 3000 |
Overvoltage category | Class I conforming to EN/IEC 61140 |
Complementary | |
Local signalling | Color indicator |
Number of cables | 1 |
Trigger cable maximum length | 20 m |
Body material | Zamak |
Head material | PA (polyamide) |
Cover material | Galvanised steel |
Reset | By pull button |
Contacts type and composition | 2 NC + 1 NO |
Contact operation | Slow-break |
Trigger cable anchor point | RH or LH side |
Connections - terminals |
Screw clamp terminal, 1 x 0.34...1 x 1 mm²
Screw clamp terminal, 1 x 0.34...2 x 0.75 mm² |
Tightening torque | 0.8…1.2 N.m |
Cable entry number | 1 tapped entry for ISO M20 cable gland |
Safety level |
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Safety reliability data | B10d = 500000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear |
Marking | CE |
Mechanical durability | 100000 cycles |
Distance between cable supports | 5 m |
[Ie] rated operational current |
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 6 A |
[Ui] rated insulation voltage |
400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60947-1 |
Positive opening | With conforming to EN/IEC 60947-5-1 |
Maximum resistance across terminals |
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A |
Short-circuit protection | 6 A cartridge fuse type gG conforming to EN/IEC 60269 |
Terminals description ISO n°1 |
(31-32)NC
(13-14)NO (21-22)NC |
Net weight | 0.455 kg |
Compatibility code | XY2CJ |
Environment | |
Standards |
Work equipment directive 2009/104/EC
UL 508 EN/ISO 13850 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 60947-5-5 Machinery directive 2006/42/EC |
Product certifications |
UL category NISD emergency stop devices
CSA CCC EAC |
Protective treatment | TC |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…70 °C |
Vibration resistance | 10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 50 gn 11 ms conforming to EN/IEC 60068-2-27 |
IP degree of protection |
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 5.6 cm |
Package 1 Width | 7.3 cm |
Package 1 Length | 24.6 cm |
Package 1 Weight | 537.0 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 10 |
Package 2 Height | 15.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 5.652 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 160 |
Package 3 Height | 75.0 cm |
Package 3 Width | 60.0 cm |
Package 3 Length | 80.0 cm |
Package 3 Weight | 81.76 kg |
Offer Sustainability | |
Sustainable offer status | Green Premium product |
REACh Regulation | REACh Declaration |
EU RoHS Directive | EU RoHS Declaration |
Mercury free | Yes |
RoHS exemption information | Yes |
Environmental Disclosure | Product Environmental Profile |
California proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |