Product Description
Electronic pressure sensors, Pressure sensors XM, sensor XMLG, 0…10 bar, G 1/4 A (male), 24 V, 4…20 mA
Electronic pressure sensors, Pressure sensors XM, sensor XMLG, 0…10 bar, G 1/4 A (male), 24 V, 4…20 mA
Main | |
---|---|
Range of product | Telemecanique Pressure sensors XM |
Product or component type | Electronic pressure sensors |
Pressure sensor type | Pressure transmitter |
Pressure sensor name | XMLG |
Pressure sensor size | 10 bar |
Fluid connection type | G 1/4A (male) conforming to DIN 3852-E |
Controlled fluid |
Air (-15…125 °C)
Corrosive fluid (-15…125 °C) Hydraulic oil (-15…125 °C) Fresh water (0…125 °C) |
Type of output signal | Analogue |
Analogue output function | 4...20 mA, 2 wires |
Electrical connection | 1 male connector M12, 3 pins |
[Us] rated supply voltage |
12 V DC (voltage limits: 8…33 V)
24 V DC (voltage limits: 8…33 V) |
Quantity per set | Set of 1 |
Type of packing | Individual |
Diameter | 22.8 mm |
Complementary | |
Pressure setting range | 0…10 bar |
Maximum permissible accidental pressure | 22 bar |
Destruction pressure | 25 bar |
Local display | Without |
Electrical circuit type | Control circuit |
Current consumption | < 20 mA |
Materials in contact with fluid |
Stainless steel type AISI 303
FPM (Viton) Ceramic |
Operating position | Any position |
Protection type |
Load short-circuit
Reverse polarity |
Surge withstand |
1 kV 42 Ohm conforming to EN/IEC 61000-4-5
500 kV 12 Ohm conforming to EN/IEC 61000-4-5 |
[Uimp] rated impulse withstand voltage | 0.5 kV |
Response time on output | < 2 ms |
Drift of the sensitivity | +/- 0.015 % of measuring range/°C |
Drift of the zero point | +/- 0.015 % of measuring range/°C |
Measurement accuracy | +/- 0.3 % of the measuring range |
Repeat accuracy | +/- 0.1 % of the measuring range |
Mechanical durability | 10000000 cycles |
Net weight | 0.095 kg |
Height | 58.1 mm |
Length | 48.5 mm |
Scale type | Fixed differential |
Environment | |
Standards |
CE
EN/IEC 61326-2-3 |
Product certifications |
UL 508
CSA C22.2 No 14 EAC |
Protective treatment | TC |
Ambient air temperature for operation | -15…85 °C |
Ambient air temperature for storage | -40…85 °C |
Vibration resistance | 20 gn (f= 9…2000 Hz) conforming to EN/IEC 60028-2-6 |
Shock resistance | 25 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Resistance to electrostatic discharge |
15 kV in air conforming to EN/IEC 61000-4-2
8 kV on contact conforming to EN/IEC 61000-4-2 |
Resistance to electromagnetic fields | 200 V/m 80…1000 Hz conforming to EN/IEC 61000-4-3 |
Resistance to fast transients | 4 kV conforming to EN/IEC 61000-4-4 |
Resistance to conducted disturbances | 30 V (0.15…80 Hz) conforming to EN/IEC 61000-4-6 |
Resistance to magnetic fields | 30 A/m 50 Hz conforming to EN/IEC 61000-4-8 |
IP degree of protection |
IP66 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529 |
NEMA degree of protection | NEMA 4 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 5.0 cm |
Package 1 Width | 10.5 cm |
Package 1 Length | 13.5 cm |
Package 1 Weight | 140.0 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 12 |
Package 2 Height | 15.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 1.925 kg |
Offer Sustainability | |
REACh Regulation | REACh Declaration |
EU RoHS Directive | EU RoHS Declaration |
Mercury free | Yes |
RoHS exemption information | Yes |
California proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Contractual warranty | |
Warranty | 18 months |