安全開關

XCSE7311

XCSE7311

Add to Quote
Category:

Product Description

Safety switch, Telemecanique Safety switches XCS, metal XCSE, 2NC+1 NO, slow break, 2 entries tapped Pg 13, 24 V

Technical Specifications

Main
Range of product Telemecanique Safety switches XCS
Product or component type Safety switch
Component name XCSE
Design Rectangular
Material Metal
Head type Key operated turret head
Contacts type and composition 2 NC + 1 NO
Contact operation Slow-break, break before make
Solenoid contacts type and composition 1 NC + 1 NO (slow-break, simultaneous)
Cable entry 2 entries tapped for Pg 13.5
Electromagnet interlocking Locking on de-energisation and unlocking on energisation of solenoid
[Us] rated supply voltage 24 V - 20...10 %
Cable outer diameter 9…12 mm
Electrical connection Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Number of poles 3
Locking options description With interlocking, locking by solenoid
Local signalling 2 LEDs (green or orange) for guard open/guard closed and locked
Signalling circuit voltage 24/48 V (voltage limits: 20...52 V)
Complementary
Positive opening With NC contact
Supply voltage type AC/DC
Supply frequency 50/60 Hz
Load factor 1
Power consumption in VA 10 VA inrush
10 VA sealed
Signalling circuit type AC/DC
Signalling circuit consumption 7 mA
Mechanical durability 1000000 cycles
Minimum actuation speed 0.01 m/s
Maximum actuation speed 0.5 m/s
[Ie] rated operational current 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
[Ithe] conventional enclosed thermal current 6 A
[Ui] rated insulation voltage 50 V conforming to EN/IEC 60947-1 for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1
Protection type Overvoltage protection for signalling circuit
Short-circuit protection 10 A cartridge fuse type gG (gl)
Actuator forcible withdrawal rtc 2000 N
Minimum actuator force for extraction 20 N
Maximum operating rate 10 cyc/mn for maximum durability
Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body material Zamak
Head material Zamak
Depth 44 mm
Height 146 mm
Width 98 mm
Net weight 1.14 kg
Environment
Standards EN/IEC 60204-1
EN/IEC 60947-5-1
EN 1088/ISO 14119
EN/ISO 12100
UL 508
CSA C22.2 No 14
Product certifications UL
CSA
Protective treatment TC
Ambient air temperature for operation -25…40 °C
Ambient air temperature for storage -40…70 °C
Vibration resistance 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance 10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class Class I conforming to EN/IEC 61140
IP degree of protection IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.6 cm
Package 1 Width 10.6 cm
Package 1 Length 14.8 cm
Package 1 Weight 1.312 kg
Unit Type of Package 2 S01
Number of Units in Package 2 4
Package 2 Height 15 cm
Package 2 Width 15 cm
Package 2 Length 40 cm
Package 2 Weight 5.5 kg
Unit Type of Package 3 P06
Number of Units in Package 3 128
Package 3 Height 77 cm
Package 3 Width 80 cm
Package 3 Length 60 cm
Package 3 Weight 179.796 kg
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation REACh Declaration
EU RoHS Directive EU RoHS Declaration
Mercury free Yes
RoHS exemption information Yes
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information
California proposition 65 WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Contractual warranty
Warranty 18 months

Documents

Brochure Date Size
Telemecanique Sensors Détection de sécurité Panorama (pdf) 5/25/2023 8.9MB
CAD Date Size
Metal safety limit switchElectromagnetic locking (zip) 8/4/2023 217.8kB
Metal safety limit switchElectromagnetic locking (zip) 8/4/2023 118.2kB
Safety switches Preventa XCS, safety interlocking switches with solenoid rectangular, metal - 3D CAD (zip) 8/15/2023 1.4MB
Certificate Date Size
XCSA/B/C... safety switches and XCSE... interlock safety switches - CSA certificate of compliance (pdf) 8/1/2023 49.9kB
XCSE... interlock safety switches (made in France) - CQC product certificate (pdf) 8/15/2023 1.3MB
XCSE... interlock safety switches (made in France) - Certificate for China compulsory product certification (pdf) 8/1/2023 1.3MB
XCSE..., XCSL5/7..., XCSLE/F... and XCSTE... interlock safety switches - UL certification record (html) 8/1/2023 300.0B
Circularity Profile Date Size
XCS LF... Metallic Safety Interlock Switch, Product End-of-Life Instructions (pdf) 8/1/2023 307.5kB
Declaration of conformity Date Size
XCSA/B/C/D/E/M/MP/P/PA/PL/PR/TA/TE/TL/TR... safety switches - EC/EU declaration of conformity (pdf) 8/15/2023 419.0kB
XCSA/B/C/D/E/M/MP/P/PA/PL/PR/TA/TE/TL/TR... safety switches - UK declaration of conformity (pdf) 8/1/2023 375.4kB
XCSE7311 EU RoHS Declaration (pdf) 8/18/2023 195.3kB
XCSE7311 REACh Declaration (pdf) 8/18/2023 195.3kB
Environmental disclosure Date Size
XCSLF3737312 Metal Safety Limit Switch, Product Environmental Profile (pdf) 8/15/2023 385.1kB
Instruction sheet Date Size
XCSE... Metal safety interlock switch, Instruction sheet (pdf) 8/15/2023 1.6MB