TeSys T

LTMR100MBD

LTMR100MBD

motor controller LTMR TeSys T – 24 V DC 100 A for Modbus

Add to Quote
Category:

Product Description

motor controller LTMR TeSys T – 24 V DC 100 A for Modbus

Technical Specifications

Download Product Datasheet

Main
range
TeSys
product name
TeSys T
device short name
LTMR
product or component type
Motor controller
device application
Equipment monitoring and control
measurement current
5…100 A
[Us] rated supply voltage
24 V DC
current consumption
56...127 mA
supply voltage limits
20.4…26.24 V DC
communication port protocol
Modbus
bus type
Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, RJ45 with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs
Complementary
[Ui] rated insulation voltage
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
[Uimp] rated impulse withstand voltage
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
short-circuit withstand
100 kA conforming to EN/IEC 60947-4-1
associated fuse rating
4 A gG for output
0.5 A gG for control circuit
protection type
Thermal overload protection
Phase unbalance
Overload (long time)
Phase failure
Thermal protection
Power factor variation
Reverse polarity protection
Overload
Locked rotor
Load fluctuation
Earth-leakage protection
network and machine diagnosis type
Remaining operating time before overload tripping
Phase fault and earth fault trip counters
Fault recording
Waiting time after overload tripping
Motor control command recording
Event recording
Starting current and time
Trip history information
Running hours counter/operating time
Trip context information
logic input number
6
input current
7 mA
current state 0 guaranteed
Logic input: < 5 V and <= 15 mA for 5 ms
current state 1 guaranteed
Logic input: < 15 V and 2...15 mA for 15 ms
maximum output switching frequency
2 Hz
load current
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
permissible power
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
maximum operating rate
1800 cyc/h
contacts type and composition
1 NO + 1 NC fault signal
3 NO
metering type
Phase current I1, I2, I3 RMS
Temperature
Average current Iavg
Earth-fault current
Imbalance current
measurement accuracy
5...15 % earth fault current internal measurement (for current > 0.3 A)
1 % voltage (100...830 V)
3 % power factor (cos φ > 0.6)
5 % earth fault current external measurement (< 5 % or 0.01 A)
+/- 30 min/year internal clock
0,02 temperature
5 % active and reactive power
0,02 current
overvoltage category
III
connection pitch
5.08 mm
connections - terminals
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
tightening torque
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
pollution degree
3
electromagnetic compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
width
91 mm
height
61 mm
depth
122.5 mm
product weight
0.53 kg
web services
Web server
compatibility code
LTMR
Environment
standards
IACS E10
CSA C22.2 No 14
EN 60947-4-1
UL 508
IEC 60947-4-1
product certifications
NOM
RMRoS
DNV
C-Tick
RINA
CSA
BV
GL
KERI
EAC
LROS (Lloyds register of shipping)
ABS
UL
CCC
ATEX
protective treatment
12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
fire resistance
650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
ambient air temperature for operation
-20…60 °C
ambient air temperature for storage
-40…80 °C
operating altitude
<= 2000 m without derating
mechanical robustness
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection
IP20
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty
18 months

Documents

More Information

Please visit the product page on our main site for more information.