按鈕開關

M22-DDLM-WS-X1/X0

Eaton Moeller® series M22 Double actuator pushbutton

Add to Quote

Product Description

Double actuator pushbutton, RMQ-Titan, Pushbutton actuator I and indicator light flush, pushbutton actuator 0 non-flush, momentary, White lens, white, black, inscribed, Bezel: titanium

Double actuator pushbutton, Product range: RMQ-Titan, Single unit, Design: Pushbutton actuator I and indicator light flush, pushbutton actuator 0 non-flush, momentary, Description: White lens, button plate: white, black, Button plate inscribed, Degree of Protection: IP66, Bezel: titanium, Connection to SmartWire-DT: yes, with SWD-RMQ connections, Front dimensions: 29,7 x 54,7, Standards: IEC/EN 60947, VDE 0660

Technical Specifications

General specifications
Product name
Eaton Moeller® series M22 Double actuator pushbutton
Part no.
M22-DDLM-WS-X1/X0
EAN
4015082848323
Product Length/Depth
30 millimetre
Product height
55 millimetre
Product width
30 millimetre
Product weight
0.015 kilogram
Compliances
GoST-R
CE Marked
Bureau Veritas
Certifications
CCC Marked
Lloyd's Register Certified
CSA Certified
VDE 0660
IEC/EN 60947-5
CSA-C22.2 No. 14-05
CE
UL 508
CSA-C22.2 No. 94-91
IEC/EN 60947
LR
GL
DNV
Product Tradename
M22
Product Type
Double actuator pushbutton
Product Sub Type
None
Globally Marketable
Yes
Features & Functions
Bezel color
Chrome
Bezel material
Plastic
Design
Pushbutton actuator I and indicator light flush, pushbutton actuator 0 non-flush
Classical
Features
Labelled
Fitted with:
Front ring
Illumination
Illuminated
Inscription
Top I, Bottom O
Lens color
White
General information
Degree of protection
NEMA 13
NEMA 3R
NEMA 12
IP66
NEMA 4X
Degree of protection (front side)
NEMA 4X
IP66
Lifespan, mechanical
200,000 Operations
Opening diameter
22.5 mm
Operating frequency
3600 Operations/h
Product category
RMQ-Titan
Size
Front dimensions: 29,7 x 54,7 mm
Suitable for
Illumination
Type
Double actuator
Ambient conditions, mechanical
Mounting position
As required
Shock resistance
Mechanical, According to IEC/EN 60068-2-27
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Ambient storage temperature - min
40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Communication
Connection to SmartWire-DT
With SWD-RMQ connections
Yes
Actuator
Actuating force
5 N
Actuator color
Black and white
Actuator function
Momentary
Spring-return
Contacts
Force for positive opening - min
0 N
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
Not applicable.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Documents

Product photo

CAD data

Instruction Leaflet

Declaration of Conformity

System overview

Drawing

Brochure

Catalog

Service

Dimensions single product

Download-Center

More Information

Please visit the product page on our main site for more information.


Learn more