Product Description
TeSys D control relay – 3 NO + 2 NC – <= 690 V - 110 V AC standard coil
Technical Specifications
Download Product Datasheet
Main
range |
TeSys
|
|
product name |
TeSys CAD
|
|
product or component type |
Control relay
|
|
device short name |
CAD
|
|
contactor application |
Control circuit
|
|
Complementary
utilisation category |
DC-13 AC-15 AC-14
|
|
pole contact composition |
3 NO + 2 NC
|
|
[Ue] rated operational voltage |
<= 690 V AC 25...400 Hz
|
|
control circuit type |
AC at 50/60 Hz
|
|
[Uc] control circuit voltage |
110 V AC 50/60 Hz
|
|
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947
|
|
[Ith] conventional free air thermal current |
10 A (at 60 °C)
|
|
Irms rated making capacity |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
|
|
[Icw] rated short-time withstand current |
100 A - 1 s 120 A - 500 ms 140 A - 100 ms
|
|
associated fuse rating |
10 A gG conforming to IEC 60947-5-1
|
|
[Ui] rated insulation voltage |
600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1
|
|
mounting support |
Plate Rail
|
|
connections - terminals |
Spring terminals 1 cable(s) 1…2.5 mm²flexible without cable end Spring terminals 2 cable(s) 1…2.5 mm²flexible without cable end Spring terminals 1 cable(s) 1…2.5 mm²solid without cable end Spring terminals 2 cable(s) 1…2.5 mm²solid without cable end
|
|
control circuit voltage limits |
Operational: 0.8...1.1 Uc at 50 Hz Operational: 0.85...1.1 Uc at 60 Hz Drop-out: 0.3...0.6 Uc
|
|
operating time |
12...22 ms coil energisation and NO closing 4...12 ms coil de-energisation and NO opening 4...19 ms coil energisation and NC opening 6...17 ms coil de-energisation and NC closing
|
|
mechanical durability |
30 Mcycles
|
|
maximum operating rate |
180 cyc/mn
|
|
inrush power in VA |
70 VA 50 Hz (at 20 °C)
|
|
hold-in power consumption in VA |
8 VA 50 Hz (at 20 °C)
|
|
minimum switching voltage |
17 V
|
|
minimum switching current |
5 mA
|
|
non-overlap time |
1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact
|
|
insulation resistance |
> 10 MOhm
|
|
mechanical robustness |
Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
|
|
height |
99 mm
|
|
width |
45 mm
|
|
depth |
84 mm
|
|
product weight |
0.58 kg
|
|
Environment
standards |
BS 4794 EN 60947-5 IEC 60947-5-1 NF C 63-140 VDE 0660
|
|
product certifications |
UL CSA
|
|
IP degree of protection |
IP2x front face conforming to VDE 0106
|
|
protective treatment |
TH conforming to IEC 60068
|
|
ambient air temperature for operation |
-40…70 °C
|
|
ambient air temperature for storage |
-60…80 °C
|
|
operating altitude |
3000 m without
|
|
Offer Sustainability
Sustainable offer status |
Green Premium product
|
|
REACh Regulation |
|
|
REACh free of SVHC |
Yes
|
|
EU RoHS Directive |
|
|
Mercury free |
Yes
|
|
RoHS exemption information |
|
|
China RoHS Regulation |
|
|
Environmental Disclosure |
|
|
Circularity Profile |
|
|
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
|
Contractual warranty
Warranty |
18 months
|
|
More Information
Please visit the product page on our main site for more information.