Product Description
Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 2NC, booted pushbutton
Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CH, 2NC, booted pushbutton
Main | |
---|---|
Range of product | Telemecanique Emergency stop rope pull switches XY2C |
Product or component type | Latching emergency stop rope pull switch |
Device short name | XY2CH |
Housing colour | Red RAL 3000 |
Overvoltage category |
Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030 |
Complementary | |
Local signalling | Without pilot light |
Number of cables | 1 |
Trigger cable maximum length | 30 m |
Body material | Zamak |
Cover material | Stainless steel |
Reset | By booted push-button |
Contacts type and composition | 2 NC |
Contact operation | Slow-break |
Trigger cable anchor point | RH or LH side |
Connections - terminals | Screw clamp terminal, 1 x 0.5...2 x 1.5 mm² |
Tightening torque | 0.8…1.2 N.m |
Cable entry number | 3 tapped entry for Pg 13.5 cable gland |
Safety level |
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Safety reliability data | B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear |
Marking | CE |
Mechanical durability | 800000 cycles |
Distance between cable supports | 5 m |
[Ie] rated operational current |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 10 A |
[Ui] rated insulation voltage |
500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 |
Positive opening | With conforming to EN/IEC 60947-5-1 |
Maximum resistance across terminals |
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A |
Short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60269 |
Terminals description ISO n°1 |
(21-22)NC
(11-22)NC |
Net weight | 0.865 kg |
Compatibility code | XY2CH |
Environment | |
Standards |
EN/ISO 13850
Machinery directive 2006/42/EC EN/IEC 60947-5-1 EN/IEC 60947-5-5 Work equipment directive 2009/104/EC EN/IEC 60204-1 |
Product certifications |
UL category NISD emergency stop devices
CCC |
Protective treatment | TC |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…70 °C |
Vibration resistance | 10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 50 gn 11 ms conforming to EN/IEC 60068-2-27 |
IP degree of protection | IP65 conforming to IEC 60529 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 9.500 cm |
Package 1 Width | 8.000 cm |
Package 1 Length | 19.700 cm |
Package 1 Weight | 1.019 kg |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 10 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 10.600 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 80 |
Package 3 Height | 75.000 cm |
Package 3 Width | 60.000 cm |
Package 3 Length | 80.000 cm |
Package 3 Weight | 94.684 kg |
Offer Sustainability | |
Sustainable offer status | Green Premium product |
REACh Regulation | REACh Declaration |
EU RoHS Directive | EU RoHS Declaration |
Mercury free | Yes |
RoHS exemption information | Yes |
Environmental Disclosure | Product Environmental Profile |
California proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Contractual warranty | |
Warranty | 18 months |