Empty enclosure

CI45E-200

Eaton xEnergy Safety Ci empty enclosure insulated

加入詢價單
分類:

産品概述

Insulated enclosure, +knockouts, HxWxD=500x375x225mm

EL Number (Norway)

4132086

Individual basic enclosure, material characteristic polycarbonate, impact-resistant, degree of protection IP65, patented cover fasteners with integrated overpressure compensation, with metric cable entry knockouts in all side walls, cable entries top and bottom, each=1xM50/32 and 2xM40/25 and 8xM25/16 and 2xM20, each side=2xM50/32 and 12xM25/16, fixing straps for wall fixing, sealable cover fasteners, full-area knockouts in the sides can be converted to a distribution board enclosure by knocking out the side walls., RAL 7035, grey (base), transparent smoky, (cover), mounting depth with mounting plate=200mm, cover type: transparent smoky , base type: knockout cover is optionally fitted by user with cylinder lock DVZ…-CI.

技術規格

General specifications
Product name
Eaton xEnergy Safety Ci empty enclosure insulated
Part no.
CI45E-200
EAN
4015080018919
Product Length/Depth
225 millimetre
Product height
500 millimetre
Product width
375 millimetre
Product weight
4.281 kilogram
Compliances
RoHS conform
Certifications
EN 62208
EN 61439-2
Product Tradename
xEnergy Safety Ci
Product Type
Empty enclosure
Product Sub Type
Insulated
Globally Marketable
Yes
Delivery program
Type
Basic enclosure Individual enclosures xEnergy Safety Ci
Color
Gray
Transparent, smoky gray (cover)
Light gray (RAL 7035, base)
Nominal current
1600 A
Technical Data - Electrical
Circuit integrity
Other
Technical Data - Mechanical
Unit type
Single unit
Surface finishing
Resistant to corrosion
Surface protection
Other
Surface treatment
Resistant to corrosion
Enclosure material
Plastic
Width in number of modular spacings
17
Mounting depth with mounting plate
200 mm
Mounting method
Surface mounted (plaster)
Material
Glass-fibre reinforced polycarbonate (base)
Halogen free
Non-reinforced polycarbonate (cover)
Degree of protection
Other
IK10
IP65
Number of conduit inlets
104
Number of modules
1
Number of openings (flange plates)
6
Number of rows
0
Built-in depth
200 mm
Internal depth
200 mm
Cover/door color
Transparent
Cover/door model
Closed
Cover/door type
None
Optional
Plate thickness (cabinet)
6 mm
Plate thickness (cover/door)
6 mm
Saline spray resistance
IEC 60068-2-11
Temperature-rise verification as per IEC 60890
Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890)
31 W
Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890)
62 W
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
36 W
Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890)
33 W
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
72 W
Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890)
67 W
Design verification as per IEC/EN 61439 - technical data
Temperature resistance
Temperature resistant: -40 °C - 120 °C (enclosure)
Temperature resistant: 80 °C (gasket)
Temperature resistant: 85 °C (enclosure bolt)
Ambient operating temperature details
-40 °C - 80 °C
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Lower part: 960 °C / cover: 850 °C
10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2.5 Lifting
30 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet.
10.2.6 Mechanical impact
IK10
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
IP65
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
Protection class 2, therefore not applicable.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Ui = 1000 V AC
10.9.3 Impulse withstand voltage
8 kV
10.9.4 Testing of enclosures made of insulating material
Meets the product standard's requirements.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
Additional information
Features
UV resistance beneath protective shield
Cover with overpressure release
Flammability characteristics (UL)
V1 (base) (UL94)
V2 (cover) (UL94)
Functions
Extension possible
Protection class
II
RAL-number
7035
Special features
With metric knockouts in all sides of the enclosure Include fixing straps for wall mounting Sealable cover fasteners Full-area knockouts in the sides can be converted to a distribution board enclosure Integrated pressure-relief mechanism for short-circuits
Suitable for
Lightning protection
Outdoor use
Used with
Eaton Switching and protection devices

文檔

更多資料

請訪問我們主站的產品頁面了解更多信息。


進一步了解