漏電保護開關

FRCMM-40/2/03-G/A-NA

Eaton Moeller series xEffect – FRCmM-NA RCCB

加入詢價單

産品概述

Residual current circuit breaker (RCCB), 40A, 2p, 300mA, type G/A

Residual current circuit-breaker FRCmM-NA, 2 pole, Rated current In: 40 A, Rated short-circuit strength Icn: 10 with back-up fuse kA, Rated fault current IΔN: 0.3 A, Switchgear for export to North America (UL-listed)

技術規格

General specifications
Product name
Eaton Moeller series xEffect - FRCmM-NA RCCB
Part no.
FRCMM-40/2/03-G/A-NA
EAN
4015081636242
Product Length/Depth
80 millimetre
Product height
71 millimetre
Product width
35 millimetre
Product weight
0.22 kilogram
Compliances
RoHS conform
Certifications
UL 1053
EN 61008
IEC 61008
ÖVE E 8601
EN45545-2
IEC 61373
Product Tradename
xEffect - FRCmM-NA
Product Type
RCCB
Product Sub Type
None
Globally Marketable
Yes
Delivery program
Application
Switchgear for export to North America (UL-listed)
Number of poles
Two-pole
Tripping time
Short time-delayed
10 ms delay at 50 Hz
8 ms delay at 60 Hz
Amperage Rating
40 A
Rated short-circuit strength
10 kA with back-up fuse
5 kA (UL, as per CSA)
Fault current rating
300 mA
Sensitivity type
Pulse-current sensitive
Impulse withstand current
3 kA (8/20 μs) surge-proof
Type
Current test marks as per inscription
Maximum operating temperature is 75 °C: Starting at 40 °C, the max. permissible continuous current decreases by 2.5% for every 1 °C
The maximum operating current of back-up fuse must not exceed the residual current circuit breaker's rated operational current
Technical Data - Electrical
Voltage rating (IEC/EN 60947-2)
240 V AC / 415 V AC
Voltage rating (UL)
480Y/277 V, 60 Hz
Rated operational voltage (Ue) - max
277 V
Rated insulation voltage (Ui)
440 V
Rated impulse withstand voltage (Uimp)
4 kV (1.2/50 µs)
4 kV
Overvoltage tested - max
530 V
Rated fault current - min
0.3 A
Rated fault current - max
0.3 A
Frequency rating
50 Hz / 60 Hz
Short-circuit rating
Max. admissible back-up fuse: 63 A gG/gL, 70 A class J fuse (UL)
Leakage current type
A
Rated residual making and breaking capacity
500 A
Admissible back-up fuse overload - max
40 A gG/gL
Rated short-time withstand current (Icw)
10 kA
Surge current capacity
3 kA
Pick-up current
200 mA
Test circuit range
184 V AC - 250 V AC, 196 V AC - 305 V AC (UL)
Pollution degree
2
Lifespan, electrical
4000 operations
Technical Data - Mechanical
Frame
45 mm
Width in number of modular spacings
2
Built-in width (number of units)
35 mm (2 SU)
Built-in depth
70.5 mm
Mounting Method
Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
DIN rail
Mounting position
As required
Degree of protection
IP20, IP40 with suitable enclosure
IP20
Status indication
White / blue
Terminals (top and bottom)
Lift terminals
Terminal capacity (solid wire)
1.5 mm² - 35 mm²
Connectable conductor cross section (solid-core) - min
1.5 mm²
Connectable conductor cross section (solid-core) - max
35 mm²
Terminal capacity (stranded cable)
16 mm² (2x)
Connectable conductor cross section (multi-wired) - min
1.5 mm²
Connectable conductor cross section (multi-wired) - max
16 mm²
Terminal capacity (cable)
M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Contact position indicator color
Red / green
Lifespan, mechanical
10000 operations
Permitted storage and transport temperature - min
-35 °C
Permitted storage and transport temperature - max
60 °C
Ambient humdity range
5 - 95 %
Climatic proofing
25-55 °C / 90-95% relative humidity according to IEC 60068-2
Design verification as per IEC/EN 61439 - technical data
Rated operational current for specified heat dissipation (In)
40 A
Heat dissipation per pole, current-dependent
3.9 W
Equipment heat dissipation, current-dependent
7.8 W
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
40 °C
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional information
Features
Residual current circuit breaker
Additional equipment possible
Fitted with:
Interlocking device
Functions
Short-time delayed tripping
Special features
FRCmM-NA
Residual current circuit breakers
Type G/A (ÖVE E 8601)
Used with
FRCmM-NA
Residual current circuit breakers
Type G/A (�VE E 8601)

文檔

更多資料

請訪問我們主站的產品頁面了解更多信息。


進一步了解