迴路保護開關

FAZ-D0,5/3-NA

Eaton Moeller series xEffect – FAZ-NA, FAZ-RT MCB

加入詢價單

産品概述

Miniature circuit breaker (MCB), 0.5 A, 3p, characteristic: D

EL Number (Norway)

1691662

Miniature circuit breaker (MCB), FAZ-NA, 3-pole, tripping characteristic: D, rated current In: 0.5 A, Switchgear for export to North America (UL-listed)

技術規格

General specifications
Product name
Eaton Moeller series xEffect - FAZ-NA, FAZ-RT MCB
Part no.
FAZ-D0,5/3-NA
EAN
4015081021338
Product Length/Depth
105 millimetre
Product height
75.5 millimetre
Product width
53.1 millimetre
Product weight
0.363 kilogram
Compliances
RoHS conform
Certifications
Specially designed for North America, suitable as BCPD
UL (Category Control Number DIVQ)
IEC/EN 60947-2
CSA (Class No. 1432-01)
UL 489, CSA C22.2 No. 5
CE marking
UL (File No. E235139)
CSA (File No. 204453)
CSA-C22.2 No. 5-09
North America (UL listed, CSA certified)
IEC 60947-2
UL 489
IEC 61373
EN45545-2
Product Tradename
xEffect - FAZ-NA, FAZ-RT
Product Type
MCB
Product Sub Type
None
Globally Marketable
Yes
Delivery program
Application
Feeder circuits, branch circuits
Switchgear for export to North America (UL-listed)
Number of poles
Three-pole
Number of poles (total)
3
Number of poles (protected)
3
Tripping characteristic
D
Release characteristic
D
Amperage Rating
0.5 A
Type
FAZ-NA
Miniature circuit breaker
Technical Data - Electrical
Voltage type
AC
Voltage rating
277 V AC / 480 V AC
Voltage rating at DC
60 V DC
Voltage rating (IEC/EN 60947-2)
415 V
Voltage rating (UL)
480Y/277 V
Rated operational voltage (Ue) - max
415 V
Rated insulation voltage (Ui)
440 V
Rated impulse withstand voltage (Uimp)
4 kV
Frequency rating - min
50 Hz
Frequency rating - max
60 Hz
Rated switching capacity (IEC/EN 60947-2)
15 kA
Rated short-circuit breaking capacity (EN 60898) at 230 V
0 kA
Rated short-circuit breaking capacity (EN 60898) at 400 V
0 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
15 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
15 kA
Selectivity class
3
Lifespan, electrical
20000 operations
Overvoltage category
III
Pollution degree
2
Direction of incoming supply
As required
Technical Data - Mechanical
Frame
45 mm
Enclosure width
105 mm
Width in number of modular spacings
3
Built-in depth
70.5 mm
Mounting width
17.7 mm
Mounting width per pole
17.7 mm
Mounting Method
Top-hat rail IEC/EN 60715
Mounting position
As required
Degree of protection
IP20
UL/CSA Type: -
IP20 (IEC)
IP40 (when fitted)
Terminals (top and bottom)
Twin-purpose terminals
Connectable conductor cross section (solid-core) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (multi-wired) - max
25 mm²
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Tightening torque
UL: 2.4 Nm (21 lb-in) for AWG 18 - AWG 12
UL: 4 Nm (36 lb-in) for AWG 6
Max. 2.4 Nm
UL: 2.8 Nm (25 lb-in) for AWG 10 - AWG 8
Design verification as per IEC/EN 61439 - technical data
Rated operational current for specified heat dissipation (In)
0.5 A
Heat dissipation per pole, current-dependent
0 W
Equipment heat dissipation, current-dependent
3.5 W
Static heat dissipation, non-current-dependent
0 W
Heat dissipation capacity
0 W
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
75 °C
Additional information
Current limiting class
3
Features
Additional equipment possible
Functions
Current limiting circuit breaker
Special features
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Used with
Miniature circuit breaker
FAZ-NA

文檔

更多資料

請訪問我們主站的產品頁面了解更多信息。


進一步了解