産品概述
variable speed drive ATV212 – 37kW – 50hp – 480V – 3ph – EMC – IP21
技術規格
Download Product Datasheet
Main
range of product |
Altivar 212
|
|
product or component type |
Variable speed drive
|
|
device short name |
ATV212
|
|
product destination |
Asynchronous motors
|
|
product specific application |
Pumps and fans in HVAC
|
|
assembly style |
With heat sink
|
|
network number of phases |
3 phases
|
|
motor power kW |
37 kW
|
|
motor power hp |
50 hp
|
|
[Us] rated supply voltage |
380...480 V - 15...10 %
|
|
supply voltage limits |
323…528 V
|
|
supply frequency |
50...60 Hz - 5...5 %
|
|
network frequency |
47.5...63 Hz
|
|
EMC filter |
Class C2 EMC filter integrated
|
|
line current |
68.9 A at 380 V 54.4 A at 480 V
|
|
Complementary
apparent power |
52 kVA at 380 V
|
|
prospective line Isc |
22 kA
|
|
continuous output current |
79 A at 380 V 79 A at 460 V
|
|
maximum transient current |
86.9 A for 60 s
|
|
speed drive output frequency |
0.5…200 Hz
|
|
nominal switching frequency |
8 kHz
|
|
switching frequency |
6...16 kHz adjustable 8...16 kHz with derating factor
|
|
speed range |
1…10
|
|
speed accuracy |
+/- 10 % of nominal slip 0.2 Tn to Tn
|
|
torque accuracy |
+/- 15 %
|
|
transient overtorque |
120 % of nominal motor torque +/- 10 % for 60 s
|
|
asynchronous motor control profile |
Flux vector control without sensor, standard Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
|
|
regulation loop |
Adjustable PI regulator
|
|
motor slip compensation |
Not available in voltage/frequency ratio motor control Automatic whatever the load Adjustable
|
|
local signalling |
1 LED (red)DC bus energized:
|
|
output voltage |
<= power supply voltage
|
|
isolation |
Electrical between power and control
|
|
type of cable |
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
|
|
electrical connection |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14 L1/R, L2/S, L3/T: terminal 50 mm² / AWG 1/0
|
|
tightening torque |
0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) 24 N.m, 212 lb.in (L1/R, L2/S, L3/T)
|
|
supply |
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
|
|
analogue input number |
2
|
|
analogue input type |
VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
|
|
sampling duration |
2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog
|
|
response time |
FM 2 ms, tolerance +/- 0.5 ms for analog output(s) FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
|
|
accuracy |
+/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C
|
|
linearity error |
VIA: +/- 0.15 % of maximum value for input VIB: +/- 0.15 % of maximum value for input FM: +/- 0.2 % for output
|
|
analogue output number |
1
|
|
analogue output type |
FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits
|
|
discrete output number |
2
|
|
discrete output type |
Configurable relay logic: (FLA, FLC) NO - 100000 cycles Configurable relay logic: (FLB, FLC) NC - 100000 cycles Configurable relay logic: (RY, RC) NO - 100000 cycles
|
|
minimum switching current |
3 mA at 24 V DC for configurable relay logic
|
|
maximum switching current |
5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
|
|
discrete input type |
F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
|
|
discrete input logic |
Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1) Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
|
|
acceleration and deceleration ramps |
Linear adjustable separately from 0.01 to 3200 s Automatic based on the load
|
|
braking to standstill |
By DC injection
|
|
protection type |
Overheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor
|
|
dielectric strength |
3535 V DC between earth and power terminals 5092 V DC between control and power terminals
|
|
insulation resistance |
>= 1 mOhm 500 V DC for 1 minute
|
|
frequency resolution |
Display unit: 0.1 Hz Analog input: 0.024/50 Hz
|
|
communication port protocol |
METASYS N2 BACnet Modbus APOGEE FLN LonWorks
|
|
connector type |
1 open style 1 RJ45
|
|
physical interface |
2-wire RS 485
|
|
transmission frame |
RTU
|
|
transmission rate |
9600 bps or 19200 bps
|
|
data format |
8 bits, 1 stop, odd even or no configurable parity
|
|
type of polarization |
No impedance
|
|
number of addresses |
1…247
|
|
communication service |
Read holding registers (03) 2 words maximum Monitoring inhibitable Write single register (06) Write multiple registers (16) 2 words maximum Time out setting from 0.1 to 100 s Read device identification (43)
|
|
option card |
Communication card for LonWorks
|
|
operating position |
Vertical +/- 10 degree
|
|
width |
240 mm
|
|
height |
550 mm
|
|
depth |
244 mm
|
|
power dissipation in W |
976 W
|
|
air flow |
334 m3/h
|
|
functionality |
Mid
|
|
specific application |
HVAC
|
|
IP degree of protection |
IP21
|
|
Variable speed drive application selection |
Building - HVAC Compressor for scroll Building - HVAC Fan Building - HVAC Pump
|
|
Motor power range AC-3 |
30…50 kW at 380…440 V 3 phases 30…50 kW at 480…500 V 3 phases
|
|
motor starter type |
Variable speed drive
|
|
Environment
electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
|
|
pollution degree |
3 conforming to IEC 61800-5-1
|
|
IP degree of protection |
IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529
|
|
vibration resistance |
1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
|
|
shock resistance |
15 gn for 11 ms conforming to IEC 60068-2-27
|
|
environmental characteristic |
Classes 3C1 conforming to IEC 60721-3-3 Classes 3S2 conforming to IEC 60721-3-3
|
|
noise level |
64 dB conforming to 86/188/EEC
|
|
operating altitude |
1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without
|
|
relative humidity |
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
|
|
ambient air temperature for operation |
-10…40 °C (without) 40…50 °C (with derating factor)
|
|
ambient air temperature for storage |
-25…70 °C
|
|
standards |
IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C3 IEC 61800-3 category C3 IEC 61800-3 category C2 EN 61800-3 IEC 61800-3 environments 1 category C1 IEC 61800-5-1 EN 61800-3 environments 1 category C1 EN 61800-3 category C3 IEC 61800-3 environments 2 category C2 EN 61800-3 category C2 EN 61800-3 environments 2 category C1 IEC 61800-3 EN 61800-3 environments 1 category C3 UL Type 1 IEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C2 EN 55011 class A group 1 EN 61800-5-1 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C2
|
|
product certifications |
UL NOM 117 C-Tick CSA
|
|
marking |
CE
|
|
Offer Sustainability
Sustainable offer status |
Green Premium product
|
|
REACh Regulation |
|
|
EU RoHS Directive |
|
|
Mercury free |
Yes
|
|
RoHS exemption information |
|
|
China RoHS Regulation |
|
|
Environmental Disclosure |
|
|
Circularity Profile |
|
|
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
|
Contractual warranty
Warranty |
18 months
|
|