Modicon M221

TM221CE24R

TM221CE24R

controller M221 24 IO relay Ethernet

Add to Quote
Category:

Product Description

controller M221 24 IO relay Ethernet

Technical Specifications

Download Product Datasheet

Main
range of product
Modicon M221
product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
discrete input number
14, discrete input conforming to IEC 61131-2 Type 1
analogue input number
2 at 0...10 V
discrete output type
Relay normally open
discrete output number
10 relay
discrete output voltage
5...125 V DC
5...250 V AC
discrete output current
2 A
Complementary
discrete I/O number
24
maximum number of I/O expansion module
7 for transistor output
7 for relay output
supply voltage limits
85…264 V
network frequency
50/60 Hz
inrush current
40 A
maximum power consumption in VA
58 VA at 100...240 V with max number of I/O expansion module
35 VA at 100...240 V without I/O expansion module
power supply output current
0.52 A 5 V for expansion bus
0.16 A 24 V for expansion bus
discrete input logic
Sink or source (positive/negative)
discrete input voltage
24 V
discrete input voltage type
DC
analogue input resolution
10 bits
LSB value
10 mV
conversion time
1 ms per channel + 1 controller cycle time for analogue input analog input
permitted overload on inputs
+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
voltage state 1 guaranteed
>= 15 V for input
voltage state 0 guaranteed
<= 5 V for input
discrete input current
7 mA for discrete input
5 mA for fast input
input impedance
3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
response time
35 µs turn-off, I2...I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
configurable filtering time
0 ms for input
3 ms for input
12 ms for input
output voltage limits
125 V DC
277 V AC
maximum current per output common
4 A at COM 2
7 A at COM 0
7 A at COM 1
absolute accuracy error
+/- 1 % of full scale for analog input
electrical durability
100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
switching frequency
20 switching operations/minute with maximum load
mechanical durability
20000000 cycles for relay output
minimum load
1 mA at 5 V DC for relay output
protection type
Without protection at 5 A
reset time
1 s
memory capacity
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up
256 kB built-in flash memory for backup of application and data
data storage equipment
2 GB SD card (optional)
battery type
BR2032 lithium non-rechargeable, battery life: 4 year(s)
backup time
1 year at 25 °C (by interruption of power supply)
execution time for 1 KInstruction
0.3 ms for event and periodic task
execution time per instruction
0.2 µs Boolean
exct time for event task
60 µs response time
maximum size of object areas
255 %TM timers
512 %M memory bits
8000 %MW memory words
255 %C counters
512 %KW constant words
realtime clock
With
clock drift
<= 30 s/month at 25 °C
regulation loop
Adjustable PID regulator up to 14 simultaneous loops
counting input number
4 fast input (HSC mode) at 100 kHz 32 bits
counter function
A/B
Single phase
Pulse/direction
integrated connection type
USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface
Ethernet with RJ45 connector
supply
(serial)serial link supply: 5 V, <200 mA
transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
communication port protocol
USB port: USB - SoMachine-Network
Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Ethernet
port Ethernet
10BASE-T/100BASE-TX 1 port with 100 m copper cable
communication service
Modbus TCP server
Modbus TCP slave device
DHCP client
Modbus TCP client
Ethernet/IP adapter
local signalling
1 LED (green)PWR:
1 LED (green)RUN:
1 LED (red)module error (ERR):
1 LED (green)SD card access (SD):
1 LED (red)BAT:
1 LED per channel (green)I/O state:
1 LED (green)SL:
Ethernet network activity (green)ACT:
Ethernet network link (yellow)Link (Link Status):
electrical connection
removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
maximum cable distance between devices
Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
insulation
Between input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
marking
CE
sensor power supply
24 V DC at 250 mA supplied by the controller
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
height
90 mm
depth
70 mm
width
110 mm
product weight
0.395 kg
Environment
standards
EN/IEC 61010-2-201
EN/IEC 61131-2
EN/IEC 60664-1
product certifications
LR
CULus
IACS E10
CSA
ABS
DNV-GL
EAC
RCM
environmental characteristic
Ordinary and hazardous location
resistance to electrostatic discharge
8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients
2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
surge withstand
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances
10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
immunity to microbreaks
10 ms
ambient air temperature for operation
-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
ambient air temperature for storage
-25…70 °C
relative humidity
10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protection
IP20 with protective cover in place
pollution degree
<= 2
operating altitude
0...2000 m
storage altitude
0…3000 m
vibration resistance
3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
shock resistance
98 m/s² for 11 ms
Offer Sustainability
Sustainable offer status
Green Premium product
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Documents

More Information

Please visit the product page on our main site for more information.


Learn more