QT50U系列8 M工作距離與耐化學品超音波感測器

74835

BAN-74835

Add to Quote

Product Description

Technical Specifications

Sensing Beam
Ultrasonic
Max Measurement Range
>1 m - <=20 m
Power
DC
PC Configurable
No
Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Time of Flight
Housing Style
Rectangular
Device Type
Sensor
Primary Housing Material
PBT
Input/Output
Analog
Indicator
LED(s)
Connection
Integral QD
Analog Output Configuration
0-10 V dc or 4-20 mA
Quick Disconnect Type
M12 (Euro)
Analog Resolution/Discrete Repeatability
1
Max Sensing Distance (mm)
6000
Minimum Sensing Distance (mm)
200
Power Supply
13-30 V dc
Delay at Power-up (ms)
1500
Adjustments
Push Button (s)
Temperature Effect (mm/°C)
Uncompensated: 0.2% of distance/°C; Compensated: 0.02% of distance/°C
Number of Pins
5
Vibration
MIL-STD-202F req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Analog Current Output Rating
1 kΩ or [(Vcc-5 V)/0.02 A] Ω, whichever is lower
Analog Voltage Output Rating
500 Ω min. load impedance
Output Protection
Protected against short circuit conditions
IP Rating
IP67
NEMA Rating
NEMA 6P
Storage Temperature (°C)
-40 to 90
Max Operating Temperature (°C)
70
Min Operating Temperature (°C)
-20
Max Op. Relative Humidity Non-Condensing (%)
100
Warm-up Time (minutes)
15
Temperature Warm-up Drift upon Power-up
< 7% of the sensing distance upon power-up.
Temp. Warm-up Drift (Notes 1)
After 5 min, the apparent switchpoint is < 0.6% of the actual position.
Temp. Warm-up Drift (Notes 2)
After 25 min, the sensing position will be stable.
Minimum Response Time (ms)
100
Rep Rate (ms)
96
Analog Linearity (mm)
+/- 0.2% of span from 200 to 8000 mm; +/- 0.1 % of span from 500 to 8000 mm (1 mm minimum)
Barrel Diameter (mm)
56
Minimum Window Size (mm)
20
Ultrasonic Frequency (kHz)
75
Power/Current Consumption (exclusive of load)
100 mA max @ 10 V dc; 40 mA max @ 30 V dc
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Clear Object Detection
Yes
Feature: Timing (Hold/Delay)
No
Feature: Chemical Resistant
Yes
Feature: Quick Disconnect
Yes
Application: Ultrasonic
Yes
Common Ethernet Protocol
No
IO Link
No
PROFINET
No
RS-232
No
RS-422
No
RS-485
No
SSI
No
Wireless
No
1-wire Serial Interface
No
Profibus
No

Documents

CAD Files

Date
Type
Size
QT50UDB/LBQ6-CRFV
6 Nov 2012
PDF
89K
QT50UDB/LBQ6-CRFV
6 Nov 2012
DXF
704K
QT50UDB/LBQ6-CRFV
6 Nov 2012
STP
5.8MB
QT50UDB/LBQ6-CRFV
6 Nov 2012
IGS
7.5MB

Technical Literature

Date
Type
Size
U-GAGE QT50U, T30U Series, PTFE Flange -- Datasheet
21 Jun 2016
DATA SHEET
357K

Certification

Date
Type
Size
DoC for QT50U
17 Aug 2017
CERTIFICATION
276K

More Information

Please visit the product page on our main site for more information.


Learn more